Steam Conversion Charts

Steam Conversion Charts

🔧 Handy Steam Conversion Charts

🔥 Boiler Horsepower (BHP) Conversions

Unit

Equivalent

1 Boiler HP

= 33,475 BTU/hr

1 Boiler HP

= 34.5 lbs of steam/hr

1 Boiler HP

≈ 0.069 GPM condensate

1 Boiler HP

= 1 gallon (for feed tank sizing)

 

💧 Steam to Water Conversions

Unit

Equivalent

1 lb of steam

≈ 1,000 BTU released (latent heat)

1 gallon of water

= 8.34 lbs

1 GPM

= 500 lbs/hr of condensate

 

🌡️ Saturated Steam Pressure & Temperature

Pressure (PSIG)

Temp (°F)

0 (Atmospheric)

212°F

2

219°F

5

227°F

10

240°F

15

250°F

30

274°F

60

307°F

 

⚙️ Pressure to Head Conversion

PSI

Feet of Head

1 PSI

= 2.31 ft

5 PSI

= 11.55 ft

10 PSI

= 23.1 ft

 

📏 Condensate Pipe Sizing (Low Pressure Return)

Condensate Flow (lbs/hr)

Suggested Pipe Size

Up to 1,500

¾"

1,500–3,000

1"

3,000–6,000

1¼"

6,000–10,000

1½"

10,000–15,000

2"



*CLICK ON ATTACHMENTS FOR PRINTABLE STEAM PRESSURE/TEMPERATURE CHART*
    • Related Articles

    • Handy Steam Conversion Charts

      ? Handy Steam Conversion Charts ? Boiler Horsepower (BHP) Conversions Unit Equivalent 1 Boiler HP = 33,475 BTU/hr 1 Boiler HP = 34.5 lbs of steam/hr 1 Boiler HP ≈ 0.069 GPM condensate 1 Boiler HP = 1 gallon (for feed tank sizing) ? Steam to Water ...
    • Sizing Condensate Return and Boiler Feeds

      Condensate and Boiler Feed Pump Sizing 1. Determine heating load: BTU/hr. or Boiler H.P. or Lbs./hr. : ____________ 2. Convert heating load from Step 1 to GPM (actual) If BTU/hr is known: _________ Btu/hr ÷ 33,475 = ___________ BHP If BHP is known: ...
    • Steam Essentials: Choosing the Right Condensate Solution

      Effectively managing condensate—the water formed when steam cools and condenses—is essential for keeping a steam system running efficiently and reliably. Two common solutions are condensate return tanks and boiler feed systems. This article explains ...
    • Laars LT Series Water Heater Propane Conversion Kits

      LT Series tankless gas water heaters are now field gas convertible (natural gas / propane). Please note that this feature is applicable to models with serial numbers beginning with “F24” and later. The conversion kits are shown in the table below. ...
    • Tech Tip: Stop Temperature Swings with the Right Mixing Valve

      Temperature swings in your water system? An oversized mixing valve might be to blame. The fix is simple: size the valve correctly for the system’s actual flow rates. The mistake often starts with sizing valves to match pipe diameters, assuming a ...