Salus Smart Relay SC824ZB WIRING
When wiring the Salus SC824ZB Smart Relay , pay special attention to wiring diagrams and schematics regarding "powered switching OR dry contact switching" .
If wiring Salus Smart Relay thru a zone panel that is considered "power switching" .
In addition, 24 volt power must be applied to the Salus Smart Relay from an outside source OTHER THAN from the zone panel IF the zone panel does not have "Auxiliary 24 Volt" terminals available.
Most manufactures pump zone panels do NOT provide AUX 24 volt power terminals, while most manufacturers zone valve panels do .
See attachment included for wiring and set up procedures.
Related Articles
RIB Relay-Up to 20 AMP output capable
RIB2401B Enclosed Relay 20 Amp SPDT with 24 Vac/dc/120 Vac Coil. *See attachment for information*
Salus/Braeburn Unit Error Code E6
Regarding the unit with Error code E6, that image is quite helpful. The device is failing to boot. Try the hard reset button, which can be found on the side of the thermostat behind the vents. Use a small screwdriver or similar object to press that ...
Laars FT Series Boiler Integration with Ecobee® Smart Thermostat
Attached is the wiring diagram for Ecobee Smart Thermostat with Laars FTHW, FTCW, FTHF wall hung and floor boilers. *Please note that the FTHW and the FTHW DO NOT HAVE 24v output terminals wherein the FTHF DOES have 24v output terminals to power the ...
TPI "Smart Probes"- Bluetooth Tools for Diagnostics and Testing HVAC Equipment.
TPI "Smart Probes.". Bluetooth Tools for Diagnostics and Testing of HVAC Equipment. TPI has a complete selection of Bluetooth test tools and equipment that can be utilized with TPI Bluetooth Combustion Analyzers or stand alone. Please see attached.
Ecobee Smart Comparisons
https://support.ecobee.com/hc/en-us/articles/360028428931-What-are-the-differences-between-ecobee-SmartThermost